1 | | [ Nov 13 05:07:59 Enabled. ] |
2 | | [ Nov 13 05:07:59 Rereading configuration. ] |
3 | | [ Nov 13 05:08:01 Rereading configuration. ] |
4 | | [ Nov 13 05:08:03 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService17 -s fd00:1122:3344:101::18 -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2024-11-13T05:08:04.010Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService17
|
7 | 2024-11-13T05:08:04.027Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService17
|
8 | 2024-11-13T05:08:04.047Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2024-11-13T05:08:04.057Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2024-11-13T05:08:04.066Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService17"
static address = fd00:1122:3344:101::18
|
11 | 2024-11-13T05:08:04.537Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2024-11-13T05:08:04.551Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_51d35f2d-6f54-4059-b52e-080f645ee9eb"
|
13 | | [ Nov 13 05:08:04 Method "start" exited with status 0. ] |