1 | | [ Dec 19 05:53:18 Enabled. ] |
2 | | [ Dec 19 05:53:18 Rereading configuration. ] |
3 | | [ Dec 19 05:53:19 Rereading configuration. ] |
4 | | [ Dec 19 05:53:24 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService17 -s fd00:1122:3344:101::e -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2024-12-19T05:53:24.570Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService17
|
7 | 2024-12-19T05:53:24.580Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService17
|
8 | 2024-12-19T05:53:24.593Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2024-12-19T05:53:24.599Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2024-12-19T05:53:24.604Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService17"
static address = fd00:1122:3344:101::e
|
11 | 2024-12-19T05:53:25.061Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2024-12-19T05:53:25.075Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_clickhouse_f6dcc1d5-458d-4c06-aac2-ae852ccaf5f0"
|
13 | | [ Dec 19 05:53:25 Method "start" exited with status 0. ] |