1 | | [ Jan 18 05:33:09 Enabled. ] |
2 | | [ Jan 18 05:33:09 Rereading configuration. ] |
3 | | [ Jan 18 05:33:14 Rereading configuration. ] |
4 | | [ Jan 18 05:33:21 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService21 -s fd00:1122:3344:101::12 -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2025-01-18T05:33:21.521Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService21
|
7 | 2025-01-18T05:33:21.531Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService21
|
8 | 2025-01-18T05:33:21.546Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2025-01-18T05:33:21.556Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2025-01-18T05:33:21.563Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService21"
static address = fd00:1122:3344:101::12
|
11 | 2025-01-18T05:33:22.024Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2025-01-18T05:33:22.039Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_39c565ae-135a-47ee-a066-91784d50b5e8"
|
13 | | [ Jan 18 05:33:22 Method "start" exited with status 0. ] |