1 | | [ Mar 17 16:40:55 Enabled. ] |
2 | | [ Mar 17 16:40:55 Rereading configuration. ] |
3 | | [ Mar 17 16:40:56 Rereading configuration. ] |
4 | | [ Mar 17 16:41:00 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService12 -s fd00:1122:3344:101::18 -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2025-03-17T16:41:00.167Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService12
|
7 | 2025-03-17T16:41:00.191Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService12
|
8 | 2025-03-17T16:41:00.206Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2025-03-17T16:41:00.215Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2025-03-17T16:41:00.224Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService12"
static address = fd00:1122:3344:101::18
|
11 | 2025-03-17T16:41:00.687Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2025-03-17T16:41:00.703Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_340c7790-5b6a-4bb7-a53d-2a6a44ece820"
|
13 | | [ Mar 17 16:41:00 Method "start" exited with status 0. ] |