1 | | [ Mar 25 01:19:18 Enabled. ] |
2 | | [ Mar 25 01:19:18 Rereading configuration. ] |
3 | | [ Mar 25 01:19:20 Rereading configuration. ] |
4 | | [ Mar 25 01:19:23 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService16 -s fd00:1122:3344:101::d -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2025-03-25T01:19:23.913Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService16
|
7 | 2025-03-25T01:19:23.923Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService16
|
8 | 2025-03-25T01:19:23.941Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2025-03-25T01:19:23.949Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2025-03-25T01:19:23.957Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService16"
static address = fd00:1122:3344:101::d
|
11 | 2025-03-25T01:19:24.419Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2025-03-25T01:19:24.431Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_oximeter_a9f260fd-b911-4f87-b07b-84934591a3eb"
|
13 | | [ Mar 25 01:19:24 Method "start" exited with status 0. ] |