1 | | [ Jul 15 21:06:00 Enabled. ] |
2 | | [ Jul 15 21:06:00 Rereading configuration. ] |
3 | | [ Jul 15 21:06:00 Rereading configuration. ] |
4 | | [ Jul 15 21:06:03 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService21 -s fd00:1122:3344:101::15 -g fd00:1122:3344:101::1"). ] |
5 | | note: configured to log to "/dev/stderr" |
6 | 2025-07-15T21:06:03.887Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService21
|
7 | 2025-07-15T21:06:03.896Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService21
|
8 | 2025-07-15T21:06:03.904Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
9 | 2025-07-15T21:06:03.909Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
10 | 2025-07-15T21:06:03.913Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService21"
static address = fd00:1122:3344:101::15
|
11 | 2025-07-15T21:06:04.375Z | INFO | zone-setup: Ensuring there is a default route
gateway = Ipv6(fd00:1122:3344:101::1)
|
12 | 2025-07-15T21:06:04.383Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_d7307103-8a76-47a9-9744-a60cf9f40236"
|
13 | | [ Jul 15 21:06:04 Method "start" exited with status 0. ] |