| 1 | | [ Apr 10 19:10:12 Enabled. ] |
| 2 | | [ Apr 10 19:10:12 Rereading configuration. ] |
| 3 | | [ Apr 10 19:10:14 Rereading configuration. ] |
| 4 | | [ Apr 10 19:10:21 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService22 -s fd00:1122:3344:101::16 -g fd00:1122:3344:101::1"). ] |
| 5 | | note: configured to log to "/dev/stderr" |
| 6 | 2026-04-10T19:10:21.487Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService22
|
| 7 | 2026-04-10T19:10:21.494Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService22
|
| 8 | 2026-04-10T19:10:21.502Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
| 9 | 2026-04-10T19:10:21.505Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
| 10 | 2026-04-10T19:10:21.509Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService22"
static address = fd00:1122:3344:101::16
|
| 11 | 2026-04-10T19:10:22.000Z | INFO | zone-setup: Ensuring there is an underlay route
gateway = fd00:1122:3344:101::1
|
| 12 | 2026-04-10T19:10:22.016Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_eff2bc3d-9949-4ec5-87f3-4ed180d8899b"
|
| 13 | | [ Apr 10 19:10:22 Method "start" exited with status 0. ] |