| 1 | | [ Apr 29 22:18:51 Enabled. ] |
| 2 | | [ Apr 29 22:18:51 Rereading configuration. ] |
| 3 | | [ Apr 29 22:18:53 Rereading configuration. ] |
| 4 | | [ Apr 29 22:18:58 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService11 -s fd00:1122:3344:101::16 -g fd00:1122:3344:101::1"). ] |
| 5 | | note: configured to log to "/dev/stderr" |
| 6 | 2026-04-29T22:18:59.129Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService11
|
| 7 | 2026-04-29T22:18:59.129Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService11
|
| 8 | 2026-04-29T22:18:59.137Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
| 9 | 2026-04-29T22:18:59.141Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
| 10 | 2026-04-29T22:18:59.144Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService11"
static address = fd00:1122:3344:101::16
|
| 11 | 2026-04-29T22:18:59.619Z | INFO | zone-setup: Ensuring there is an underlay route
gateway = fd00:1122:3344:101::1
|
| 12 | 2026-04-29T22:18:59.634Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_crucible_3f736c51-204c-4679-ab53-8bbe8dac6f7f"
|
| 13 | | [ Apr 29 22:18:59 Method "start" exited with status 0. ] |