| 1 | | [ May 19 16:47:42 Enabled. ] |
| 2 | | [ May 19 16:47:42 Rereading configuration. ] |
| 3 | | [ May 19 16:47:45 Rereading configuration. ] |
| 4 | | [ May 19 16:47:47 Executing start method ("/opt/oxide/zone-setup-cli/bin/zone-setup common-networking -d oxControlService24 -s fd00:1122:3344:101::b -g fd00:1122:3344:101::1"). ] |
| 5 | | note: configured to log to "/dev/stderr" |
| 6 | 2026-05-19T16:47:47.515Z | INFO | zone-setup: Ensuring IP interface exists on datalink
datalink = oxControlService24
|
| 7 | 2026-05-19T16:47:47.520Z | INFO | zone-setup: Setting MTU to 9000 for IPv6 and IPv4
datalink = oxControlService24
|
| 8 | 2026-05-19T16:47:47.526Z | INFO | zone-setup: Setting TCP recv_buf size to 1 MB
|
| 9 | 2026-05-19T16:47:47.529Z | INFO | zone-setup: Setting TCP congestion control algorithm to cubic
|
| 10 | 2026-05-19T16:47:47.532Z | INFO | zone-setup: Ensuring static and auto-configured addresses are set on the IP interface
data link = "oxControlService24"
static address = fd00:1122:3344:101::b
|
| 11 | 2026-05-19T16:47:47.996Z | INFO | zone-setup: Ensuring there is an underlay route
gateway = fd00:1122:3344:101::1
|
| 12 | 2026-05-19T16:47:48.008Z | INFO | zone-setup: Populating hosts file for zone
zonename = "oxz_nexus_3ab219f1-c650-4b13-9b67-9e3f33f1dbb8"
|
| 13 | | [ May 19 16:47:48 Method "start" exited with status 0. ] |